Company Profile |
| |
Unitech Water Solution is as an Authorized Service Provider of FLIR, a world leader in the field of thermal imaging system, headquartered at Sweden and NASDAQ listed company. FLIR, a global company with over 90 + years experience in the field of thermal imaging provides solutions to wide range of application ranging from industrial applications to space and military applications. FLIR offers complete customer solution by providing the world class cameras, training and after sales service to their customer. |
| |
 |
 |
| |
|
| FLIR I SERIES |
FLIR T SERIES |
|
|
| |
Principle & Application |
Thermal imagers work on the principle of capturing and analyses infrared energy emitted by any hot object. This is a non contact measuring system. FLIR thermal imager is light weight, compact and easy to use. They can be used to address various electrical, mechanical and civil engineering application.
Thermal cameras are mainly used in preventive maintenance and predictive maintenance of electrical and mechanical equipments. Thermal imagers identify and locate the problems from a safe distance ensuring operator safety. They identify the faults before repair becomes expensive or equipment fails. Detects the problems not visible with nicked eye. No shutdowns are required for the inspection and can be used when equipment is in operation. They help in planning preventative maintenance schedule by providing the health of the equipment under consideration. The images captured and stored by thermal imagers can be compared over the period for quantative and qualitative analyses. |
| |
| Some of the examples of electrical applications : |
| |
- Measurement of insulation failure in cables by reading the temperature of the cable at the termination point, improper crimping of lugs at cable ends etc.
- Failures due to local heating or over load.
- Failures in MCC and PCC panels, connector box, junction box due to lose connection which result in local heating etc.
- Heating effect of contacts in ELCB, MCCB, isolators, bus bar and CT-PT etc.
- Loose connections at the terminal boxes which may cause problems in the critical equipments in the hospitals, data centers, banks, telecommunication panels etc. There are many more application where heating effect is not visible with nicked eye.
|
| |
| Some of the examples of mechanical applications : |
| |
- Identification bearing health in motors, pumps by measuring friction temperature.
- Failure of insulation of bricks in the furnace.
- Measuring of temperature of steel slabs, sections and rods.
- Measurement of temperature in the rotary furnace and many more.
|
|
|
|
 |
 |
 |
 |
|